-> R2 = 0.43 (based on 10 days field exposure) -> The major cross sensitivities showed by the CairClip NO2 were in order of magnitude: aging O3 filtering, long-term drift, relative humidity and temperature and wind velocity -> Clear Ozone interference -> Correctionfor T, RH -> More sensitive for O3 than for NO2
https://vaquums.eu/no9_cairclipno2-report-of-the-laboratory-and-in-situ-validation-of-micro-sensors-and-evaluation-of-suitability-of-model-equations
https://vaquums.eu/@@site-logo/life_vaquums_eu.png
NO9_CairClipNO2 Report of the laboratory and in-situ validation of micro-sensors and evaluation of suitability of model equations.
-> R2 = 0.43 (based on 10 days field exposure) -> The major cross sensitivities showed by the CairClip NO2 were in order of magnitude: aging O3 filtering, long-term drift, relative humidity and temperature and wind velocity -> Clear Ozone interference -> Correctionfor T, RH -> More sensitive for O3 than for NO2
Author: Spinelle et al
Publication date: October 2013
Published in journal:
report
Pollutant(s) discussed:
NO2